HRS Guidelines Bundle (free trial)

Cardiac Physiologic Pacing for the Avoidance and Mitigation of Heart Failure

Heart Rhythm Society GUIDELINES Apps brought to you free pf charge, courtesy of Guideline Central. Enjoy!

Issue link: https://eguideline.guidelinecentral.com/i/1499526

Contents of this Issue

Navigation

Page 16 of 47

17 PICM with high-burden RVP COR LOE Recommendations 1 B-NR 1. In patients with a CIED with a decline in LV function or worsening of HF symptoms attributed to substantial ventricular pacing, CRT with BiV pacing is recommended to improve LV function and improve HF symptoms. 2a B-NR 2. In patients with a CIED with a decline in LV function or worsening of HF symptoms attributed to substantial ventricular pacing, revision of CIED to a CSP device can be beneficial to improve LV function and symptoms of HF. Survival <1 year COR LOE Recommendation 1 C-EO 1. In patients with a life expectancy of <1 year, the decision to implant CPP should incorporate shared decision-making, taking into account the potential improvement in quality of life balanced against the risk of procedural complications.

Articles in this issue

Archives of this issue

view archives of HRS Guidelines Bundle (free trial) - Cardiac Physiologic Pacing for the Avoidance and Mitigation of Heart Failure