Table 2. Choice of Pacemaker Generator in Selected
Indications for Pacing
Pacemaker
Generator
Sinus Node
Dysfunction
Single-chamber
atrial pacemaker
• No suspected
• Not appropriate • Not appropriate
abnormality of
AV conduction
and not at
increased risk for
future AV block
• Maintenance of
AV synchrony
during pacing
desired
• Maintenance of
• Chronic AF
• Chronic AF
AV synchrony
or other atrial
or other atrial
during pacing not
tachyarrhythmia
tachyarrhythmia
necessary
or maintenance
of AV synchrony
during pacing not
necessary
• Rate response
• Rate response
• Rate response
available if
available if
available if desired
desired
desired
Single-chamber
ventricular
pacemaker
Atrioventricular
Block
Neurally Mediated
Syncope or
Carotid Sinus
Hypersensitivity
• AV synchrony
during pacing
desired
• Rate response
available if
desired
• Sinus mechanism
present
• Suspected
abnormality of
AV conduction
or increased risk
for future AV
block
• Rate response
available if
desired
Dual-chamber
pacemaker
• AV synchrony
during pacing
desired
• Rate response
available if desired
• Atrial pacing
desired
• Rate response
available if desired
Single-lead, atrialsensing ventricular
pacemaker
• Not appropriate
• Desire to limit
the number of
pacemaker leads
• Not appropriate
15