68 Treatment Table 28. High-Risk Features in Uncomplicated Acute Type B Aortic Dissection High-Risk Imaging Findings Maximal aortic diameter >40 mm False-lumen diameter >20–22 mm Entry tear >10 mm Entry tear on lesser curvature Increase in total aortic diameter of >5 mm between serial imaging studies Bloody pleural effusion Imaging-only evidence of malperfusion High-Risk Clinical Findings Refractory hypertension despite >3 different classes of antihypertensive medications at maximal recommended or tolerated doses Refractory pain persisting >12 h despite maximal recommended or tolerated doses Need for readmission